RB Eco Power

OUR PRODUCTS


Genset Controller Units

Genset Monitoring System (GMS 543)
Genset Monitoring System (GMS 541)
Single Phase Genset Controller
Line Voltage Monitor (LVM)

Engine Safety Units

Engine Safety Unit
Fail Safety Unit (FSU 01)
KRB 101
KRB 202
HR Meter
HR01
W Point HR Meter

Display Units

Digital Pressure Indicator
(Resistive I/P)
Digital Pressure Indicator
(4-20mA Current I/P)
Digital Fuel Level Indicator
(Resistive I/P)
Digital Fuel Level Indicator
(4-20mA Current I/P)
Digital Temperature Indicator
(Resistive I/P)
Digital Temperature Indicator
(4-20mA Current I/P)

Relay Cards

Interface Card Green
Interface Card White
DC Interface Card
GC/MC Contactor Control Card
GMS Relay Card
Start Stop Relay card
2 Way Relay card
Battery Charger
Charge Lamp
Different Types of Magnetic Pickup

× Image

Genset Monitoring System (GMS 541)


Features:

  • Displays RPM, Frequency, Hours
  • Battery operated, available in 12VDC & 24VDC models
  • Built in single phase / three phase monitor and protection
  • Integration of all engine and alternator parameters
  • Under voltage/over voltage protection
  • Flexible AMF logic
  • Auto / Manual Modes
  • 5 Digital Inputs
  • 4 Analog Inputs
  • 5 Relay outputs
  • Periodic Start / Stop facility
  • LED Indications for genset status & Alarms
  • Complied with standard :
    1. Radiated Emission as per EN55022
    2. Radiated EM Field Immunity as per IEC 61000-4-3
    3. Electrical Fast Transients / Burst ( EFT/B ) Immunity as per IEC 61000-4-4
    4. Combination Wave Surge Immunity as per IEC 61000-4-5
    5. Transient Immunity on Supply Line Test as per ISO 7637-2:2004(E) Standard
    6. IP56 Protection as per IS: 13947 (Part 1)-1993

Specifications:

  • Dimension:- 96*96*62
  • Supply:- 8-35 VDC
  • VAC input rating: 415 VAC
  • RS 485 Communication.


× Image

Genset Monitoring System (GMS 543)


Features:

  • Displays RPM, Frequency, Hours
  • Battery operated, available in12VDC & 24VDC models
  • Built in single phase / three phase monitor and protection
  • Integration of all engine and alternator parameters
  • Events Log
  • Mains Voltage Measurement
  • Under voltage/over voltage protection
  • Flexible AMF logic
  • Auto / Manual Modes
  • 8 Digital Inputs
  • 4 Analog Inputs
  • 8 Relay outputs
  • Periodic Start / Stop facility  
  • LED Indications for genset status & Alarms

Specifications:

  • Dimension:- 180 x 126 x 51mm
  • Supply:- 8-36 VDC
  • VAC input rating: 450 VAC ( L-N) 750 VAC (L-L)
  • RS 485 communication.


× Image

Digital Pressure Indicator
(Resistive I/P)


Features:

  • Displays Oil pressure
  • Reverse battery protection
  • Short Circuit protection
  • IP65 Protection
  • Complied tests as per standard:
    1. EFT as per IEC 61000 4-4
    2. Surge as per IEC 61000 4-5
    3. Radiated Susceptibility test as per IEC61000 4-3
    4. Radiated emission Test as per CISPR 11/CISPR 22
    5. IP 65 as per IEC 60529
    6. Temperature Test : - 20°C to + 70°C
    7. Vibration : 5G

Specifications:

  • Sensor Type:- Resistive
  • Current Range:- 0-10 Bar
  • Dimensions : Round Dia: 60mm , Depth : 69mm
  • Supply Voltage : 8V-30VDC
  • Operating Temperature: - 20°C to + 70°C


× Image

Line Voltage Monitor (LVM)


Features:

  • Single/ Three phase selection
  • Fixed/adjustable under/Over voltage trip settings
  • Two relay output Contacts

Specifications:

  • Dimensions :- 96 X 96 X 72 mm
  • Supply :- 85 – 270 VAC
  • Trip Time Delay :-1-10 secs. (adjustable)


× Image

Battery Charger


Features:

  • Two models :- 12V, 6Amp & 12V, 10Amp
  • Under voltage/Over voltage protection
  • Protected latching mode for battery reverse polarity
  • Wall mounting
  • Next versions will have display to show voltage

Specifications:

  • Dimensions :-170*110*85mm
  • Supply :- 150-300 VAC


× Image

HR Meter


Features:

  • Display Engine Hours
  • Display Engine RPM
  • Field Settable
  • Built in over speed relay

Specifications:

  • Dimension: 72*72*80
  • Supply: 8 – 30VDC


× Image

HR01


Features:

  • Display Engine Hours
  • Display Engine RPM
  • Field Settable
  • Built in over speed & under speed relay

Specifications:

  • Supply Voltage : 8-30 VDC
  • Dimensions : 72 X 72 X 106 VDC


× Image

KRB 101


Features:

  • Displays Engine Hours
  • Reverse battery indication
  • 4 Fault inputs
  • Fuse fail indication
  • Built in Charge lamp
  • LOP bypass timer
  • 70 Amp contact for stop solenoid
  • Reverse battery protection relay for charging alternator
  • Stop timer for ES(=Energized to stop) type solenoid  

Specifications:

  • Dimension: 144 X 100 X 72
  • Supply: 8 – 30VDC
  • Relay contact 70Amp


× Image

KRB 202


Features:

  • Displays Engine Hours
  • Reverse battery indication
  • 4 Fault inputs
  • Fuse fail indication
  • Built in Charge lamp
  • LOP bypass timer
  • 70 Amp contact for stop solenoid
  • Reverse battery protection relay for charging alternator
  • Stop timer for ES(=Energized to stop) type solenoid  

Specifications:

  • Dimension: 144 x 100 x 72 mm
  • Supply: 8 - 30 VDC
  • Relay contact 70Amp


× Image

Fail Safe Unit (FSU 01)


Features:

  • 4 Fault Detection
  • 2 Fault inputs
  • Fuse fail indication
  • Built in Charge lamp
  • LOP bypass timer
  • Stop timer for ES type Solenoid
  • Built in buzzer

Specifications:

  • Dimension:- 72 X 72 X 120
  • Supply:- 8-35VDC
  • Relay Contact :- 70 Amp max


× Image

Engine Safety Unit


Features:

  • 6 Fault Detection
  • 4 Fault inputs
  • Fuse fail indication
  • Built in Charge lamp
  • LOP bypass timer
  • Stop timer for ES type Solenoid

Specifications:

  • Dimension :- 72 X 72 X 120
  • Supply :- 8-35VDC
  • Relay Contact :- 70 Amp max


× Image

Charge Lamp


Features:

  • Charging Alternator Indication

Specifications:

  • Supply: 8- 24 VDC supply
  • Dimensions: 58mm X 28 mm


× Image

Interface Card Green


Features:

  • Negative switching
  • Avoids Loose Connections.
  • Re settable Fuse will provide protection against high Voltage & current.
  • 4 KV Isolation for AC power connector
  • Back EMF protection.
  • Troubleshooting is easy
  • Connector Input: Battery Power, 3-Phase input from Alternator, Genset's Analog Sensor & Digital input
  • Connector Output: Battery Power to controller, starter motor, Stop Solenoid, MC, GC, Auto, Canopy Lamp o/p, 3-Phase o/p to controller

Specifications:

  • Supply Voltage : 12VDC
  • Dimensions : 245X89X65 mm


× Image

Interface Card White


Features:

  • Positive switching
  • Avoids Loose Connections.
  • Re settable Fuse will provide protection against high Voltage & current.
  • 4 KV Isolation for AC power connector
  • Back EMF protection.
  • Troubleshooting is easy
  • Connector Input: Battery Power, 3-Phase input from Alternator, Genset's Analog Sensor & Digital input
  • Connector Output: Battery Power to controller, 3-Phase o/p to controller, starter motor, Stop Solenoid, MC, GC, Auto, Canopy Lamp o/p

Specifications:

  • Supply Voltage : 12VDC
  • Dimensions : 200X72X35 mm


× Image

DC Interface Card


Features:

  • Avoids Loose Connections.
  • Resettable Fuse will provide protection against high Voltage & current.
  • Back EMF protection.
  • Troubleshooting is easy.
  • Connector Input: Battery Power, Relay Coil Control I/P, Genset's Analog Sensor & Digital input
  • Connector Output: Battery power to Controller, Starter motor, Stop Solenoid, Auto & Fault Relay O/P

Specifications:

  • Dimensions:- 202X89X65mm
  • Supply Voltage : 12VDC


× Image

Relay Card


Features:

  • Two relays i.e., Start and Stop are provided with LED Indicators.

Specifications:

  • Supply Voltage : 12VDC
  • Dimensions : 82X89X65 mm
  • Relay Contact: 70Amps Max


× Image

GMS Relay Card


Features:

  • Five relays for Start, Stop, MC, GC and Hooter are provided.

Specifications:

  • Supply Voltage : 12VDC
  • Dimensions : 105x 89X65 mm
  • Relay Contact : 70 Amp for Start & Stop Relay


× Image

GC/MC Contactor Control Card


Features:

  • 3 Configurable relay outputs with LED Indicators.
  • Resettable Fuse will give protection against High Voltage & High Current.

Specifications:

  • Supply Voltage : 12VDC
  • Dimensions : 132X89X60 mm
  • Relay Contacts: 10 Amps


× Image

Single Phase Genset Controller


Features:

  • Manual Start-Stop and auto stop on fault
  • Monitors Genset Parameters monitoring
    1. Battery Voltage
    2. Fuel Level
    3. Single Phase Voltage
    4. Frequency
    5. Engine Run Hour
    6. Digital Input: LOP, Temperature
  • ETR or ETS Genset Start - Stop Operation.
  • Fault Detection & Warning indications
  • Over & Under Voltage Protection

Specifications:

  • Dimensions : 72 x 72 x 112mm
  • Supply Voltage : 8 - 30 VDC
  • VAC Input Rating :- 50 – 320 VAC
  • Five LED Indications.
  • 1Analog Input - Resistive type
  • 2 Digital Input : Oil pressure, Temperature
  • Low Side Relay Output : Start, Stop
  • Genset Single Phase Input.
  • Operating Temperature: - 20°C o + 70°C


× Image

Digital Fuel Level Indicator
(Resistive I/P)


Features:

  • Displays Fuel level
  • Reverse battery protection
  • Short Circuit protection
  • IP65 Protection
  • Complied tests as per standard:
    1. EFT as per IEC 61000 4-4
    2. Surge as per IEC 61000 4-5
    3. Radiated Susceptibility test as per IEC61000 4-3
    4. Radiated emission Test as per CISPR 11/CISPR 22
    5. IP 65 as per IEC 60529
    6. Temperature Test : - 20°C to + 70°C
    7. Vibration: 5G

Specifications:

  • Sensor Type:- Resistive
  • Range:- 0 - 100%
  • Dimensions : Round Dia: 60mm Depth : 69mm
  • Supply Voltage : 8V-30VDC
  • Operating Temperature: - 20°C to + 70°C


× Image

Digital Temperature Indicator
(Resistive I/P)


Features:

  • Displays Engine Temperature
  • Reverse battery protection
  • Short Circuit protection
  • IP65 Protection
  • Complied tests as per standard:
    1. EFT as per IEC 61000 4-4
    2. Surge as per IEC 61000 4-5
    3. Radiated Susceptibility test as per IEC61000 4-3
    4. Radiated emission Test as per CISPR 11/CISPR 22
    5. IP 65 as per IEC 60529
    6. Temperature Test: - 20°C to + 70°C
    7. Vibration : 5G

Specifications:

  • Sensor Type:-Resistive
  • Range:- 40°C- 150°C
  • Dimensions : Round Dia: 60mm Depth : 69mm
  • Supply Voltage : 8V-30VDC
  • Operating Temperature: - 20°C to + 70°C


×

Different Types of Magnetic Pickup


Image
  • Total Length of MPU:- 60mm
  • Threading Length:- 45mm
  • Cable Length: 350mm ±25mm
  • Auto grade 2 Pin Male Connector
  • MS Zinc Plated Pin
  • SS Body
  • M16 x1.5 Threading as per 6G
  • 5x19mm AF Hex Nut

Image
  • Dual Output.
  • Total Length of MPU:-96mm
  • Threading Length:- 81mm
  • Cable Length: 200mm±25mm
  • Auto grade 2 Pin Male x 2 Connector
  • MS Zinc Plated Pin
  • SS Body(Electro Polished Finish)
  • M16x1.5 Threading as per 6G
  • 7x22mm AF Hex Nut

Image
  • MPU Total Length:- 86mm
  • Threading Length:- 76mm
  • Cable Length: 100mm ±25mm
  • Auto grade 2 Pin Male Connector
  • MS Zinc Plated Pin
  • SS Body
  • 5/8 UNF-2A Threading
  • 6x19mm AF Hex Nut

Image
  • Total Length of MPU:- 80mm
  • Threading Length:- 60mm
  • Cable Length: 200mm ±25mm
  • Auto grade 2 Pin Male Connector
  • MS Zinc Plated Pin
  • SS Body
  • M16 x1.5 Threading as per 6G
  • 5x19mm AF Hex Nut

Image
  • Total Length of MPU:- 80mm
  • Threading Length:- 60mm
  • Cable Length: 200mm ±25mm
  • Auto grade 2 Pin Male Connector
  • MS Zinc Plated Pin
  • SS Body
  • M16 x1.5 Threading as per 6G
  • 5x19mm AF Hex Nut

Image
  • Total Length of MPU: 96 mm
  • Threading Length:- 81mm
  • Cable Length: 250mm, 2 wires for Coil 1 & Coil 2
  • SS Body
  • M16 x1.5 Threading as per 6G
  • 7x22mm AF Hex Nut
  • Available in Single & Dual Output


× Image

W Point HR Meter


Features:

  • Display Engine Hours
  • Display Engine RPM
  • Field Settable
  • Battery Charging Alternator Input
  • Built in over speed & under speed relay

Specifications:

  • Dimensions: 72 x 72 x 106 mm
  • Supply Voltage: 8 – 30VDC
  • Analog(W-Point) Input Rating :- 8-24VAC


× Image

Digital Pressure Indicator
(4-20mA Current I/P)


Features:

  • Displays Oil pressure
  • Reverse battery protection
  • Short Circuit protection
  • IP65 Protection
  • Complied tests as per standard:
    1. EFT as per IEC 61000 4-4
    2. Surge as per IEC 61000 4-5
    3. Radiated Susceptibility test as per IEC61000 4-3
    4. Radiated emission Test as per CISPR 11/CISPR 22
    5. IP 65 as per IEC 60529
    6. Temperature Test: - 20°C to + 70°C
    7. Vibration: 5G

Specifications:

  • Sensor Type:- 4-20mA Current
  • Range:- 0-10 Bar
  • Dimensions : Round Dia: 60mm, Depth : 69mm
  • Supply Voltage : 8-30VDC
  • Operating Temperature: - 20°C to + 70°C


× Image

Digital Fuel Level Indicator
(4-20mA Current I/P)


Features:

  • Displays Engine Temperature
  • Reverse battery protection
  • Short Circuit protection
  • IP65 Protection
  • Complied tests as per standard:
    1. EFT as per IEC 61000 4-4
    2. Surge as per IEC 61000 4-5
    3. Radiated Susceptibility test as per IEC61000 4-3
    4. Radiated emission Test as per CISPR 11/CISPR 22
    5. IP 65 as per IEC 60529
    6. Temperature Test: - 20°C to + 70°C
    7. Vibration : 5G

Specifications:

  • Sensor Type:-4-20mA Current
  • Range:- 40°C- 150°C
  • Dimensions : Round Dia: 60mm Depth : 69mm
  • Supply Voltage : 8V-30VDC
  • Operating Temperature: - 20°C to + 70°C


× Image

Digital Temperature Indicator
(4-20mA Current I/P)


Features:

  • Displays Engine Temperature
  • Reverse battery protection
  • Short Circuit protection
  • IP65 Protection
  • Complied tests as per standard:
    1. EFT as per IEC 61000 4-4
    2. Surge as per IEC 61000 4-5
    3. Radiated Susceptibility test as per IEC61000 4-3
    4. Radiated emission Test as per CISPR 11/CISPR 22
    5. IP 65 as per IEC 60529
    6. Temperature Test: - 20°C to + 70°C
    7. Vibration : 5G

Specifications:

  • Sensor Type:- 4-20mA Current
  • Range:- 40°C - 150°C
  • Dimensions : Round Dia: 60mm Depth : 69mm
  • Supply Voltage : 8-30VDC
  • Operating Temperature: - 20°C to + 70°C


× Image

2 Way Relay Card


Features:

  • Two Change over Relays provided with LED Indication

Specifications:

  • Dimensions : 60 X89X65 mm
  • Supply Voltage : 12VDC
  • Relay Contact : 5Amp