Interface Card White
A positive-switching interface card that neatly connects the genset to its controller, with fuse and back-EMF protection.
Key features
- Positive switching
- Back EMF protection.
- Troubleshooting is easy
- Avoids Loose Connections.
- 4 KV Isolation for AC power connector
- Re settable Fuse will provide protection against high Voltage & current.
- Connector Input: Battery Power, 3-Phase input from Alternator, Genset's Analog Sensor & Digital input
- Connector Output: Battery Power to controller, 3-Phase o/p to controller, starter motor, Stop Solenoid, MC, GC, Auto, Canopy Lamp o/p
Made in Pune
Factory tested
Engineer support
About the Interface Card White
The Interface Card (White) sits between the genset and its controller and takes care of all the connections in one place. Battery power, three phase alternator input, analog sensors and digital inputs come in on one side; battery power to the controller, three phase output, starter motor, stop solenoid, MC, GC, Auto and canopy lamp outputs leave on the other.
This card uses positive switching. Proper connectors avoid loose wiring, a resettable fuse protects against high voltage and current, the AC power connector has 4 kV isolation, and back-EMF protection guards the electronics when relays and solenoids switch off. Troubleshooting is easy because every signal has its own clearly marked terminal. It works on 12 V DC.
Specifications
- Supply Voltage
- 12 V DC
- Dimensions
- 245 × 72 × 36 mm
- Isolation
- 4 kV
- Relay Contact
- 230 V AC, 70 Amp max (power relays); 230 V AC, 10 Amp max (changeover relays)
What the technical words mean
- MC / GC
- Mains Contactor and Genset Contactor: the two contactors that connect the load to mains power or to the generator.
- Back EMF protection
- Relay coils and solenoids produce a voltage spike when switched off. This protection absorbs it so the electronics are not damaged.
- Resettable fuse
- A fuse that trips on overload and resets itself once the fault is removed, so it never needs replacing.
- Positive / negative switching
- Whether the controller output connects a load to battery positive or to battery negative. The interface card must match the controller.
- Changeover relay
- A relay with both normally open and normally closed contacts, so it can switch one circuit on while switching another off.
More Relay Cards
View all →
1 Way Double Changeover Relay Card
A single double-changeover relay with LED indication, for 12 V or 24 V DC systems.
2 Way Double Changeover Relay Card
Two double-changeover relays with LED indication on one compact card, for 12 V or 24 V DC.
Start Relay Card
One heavy-duty start relay with LED indicator, rated up to 70 Amps on 12 V DC.
Start Stop Relay Card
Heavy-duty start and stop relays with LED indicators, rated up to 70 Amps.